One Sided Highly Absorbing Noise Barrier


Distributed by KCI Kraft Consulting Inc
Brand: Forster Noise Control

One sided highly absorbing noise barrier panel, according to ZTV-LSW 06, EN 1793 1-3 and EN 1794 1-2,
CE-label acc. to EN 14388, build with upper- and lower chord profiles made of aluminium extrusions, frontand
rear panel double-corrugated for stiffening, front panel perforated.
Absorbing panel: 40 mm thick rock-wool slab with 100 kg/m³, front side covered with black glass fleece (hydrophobic).
End covers made of deepdrawed aluminium-sheets, insulated with rubber seals which are vertically adjusted
to the end covers, as well as a sealing clip-profile made of extrusion profiles.
For installation in-between steel columns of type HE-160 (optional HE-180, 200, 220).

Categories: 
Fencing, Glare Screens, and Noise Barriers | Noise Barriers
  • American Society for Testing and Materials
    • ASTM C423-09a - Sound Absorption and Sound Absorption Coefficients by the Reverberation Room Method
  • Other Standards
    • BS EN 14388:2005 - Road traffic noise reducing devices. Specifications
    • BS EN 1793-1:1998 - Road traffic noise reducing devices. Test method for determining the acoustic performance. Intrinsic characteristics of sound absorption.
    • BS EN 1794-2:2003 - Road traffic noise reducing devices. Non-acoustic performance. General safety and environmental requirements
    • BS EN ISO 10140-1:2010+A1:2012 - Acoustics. Laboratory measurement of sound insulation of building elementsApplication rules for specific products
    • BS EN ISO 10140-2:2010 - Acoustics. Laboratory measurement of sound insulation of building elementsMeasurement of airborne sound insulation
    • BS EN ISO 10140-3:2010 - Acoustics. Laboratory measurement of sound insulation of building elements. Measurement of impact sound insulation
    • BS EN ISO 10140-4:2010 - Acoustics. Laboratory measurement of sound insulation of building elements. Measurement procedures and requirements
    • BS EN ISO 11654:1997 - Acoustics. Sound absorbers for use in buildings. Rating of sound absorption
    • ISO 14001:2004 - Environmental management systems -- Requirements with guidance for use
    • ISO 354:2003 - Acoustics -- Measurement of sound absorption in a reverberation room
    • ISO 9001:2008 - Quality management systems --Requirements
    • ISO 9613-1:1993 - Acoustics -- Attenuation of sound during propagation outdoors -- Part 1: Calculation of the absorption of sound by the atmosphere
    • ISO 9613-2:1996 - Acoustics -- Attenuation of sound during propagation outdoors -- Part 2: General method of calculation


Rainer Kraft, President
KCI Kraft Consulting Inc
1773 146 Street
Surrey BC V4A 5V4
Rainer@KraftConsulting.ca
http://www.KraftConsulting.ca
Phone: (604) 655-3577
Fax: (604) 245-0041